Pro Plumbers · 24 November 2026
How to bleed a radiator safely, step by step

A radiator that feels hot along its lower half but stays cool near the top is almost always holding a pocket of air. Air collects at the highest point of each panel because it is lighter than water, and while it sits there the hot water cannot fill the whole radiator. Letting that air out is called bleeding, and it is one of the few heating jobs most householders can do with a cheap key and a cloth.
This guide covers the tools you need, the order to work in, what the hissing and spluttering mean, and how to check the boiler afterwards. It also explains when bleeding will not help, so you do not keep releasing air from a system that has a different fault.
Signs a radiator needs bleeding
Feel each radiator once the heating has been on for twenty minutes or so. A cold band across the top with a warm lower section points to air. You may also hear gurgling or trickling inside the panel, especially when the pump starts. A radiator that is cold at the bottom but hot at the top is a different problem, usually sludge settling in the base, and bleeding will not shift it.
If every radiator in the house is cold, the cause is more likely to be the boiler, the pump or the controls than trapped air. In that case bleeding one panel will not bring the system back to life.
What you need before you start
You need a radiator key, which is a small square-socket key sold in hardware shops. Some modern valves take a flat screwdriver instead. Have an old towel or cloth to wrap around the valve and a small cup or container to catch drips, because the water inside is often dark and can stain carpets.
Find the bleed valve first. It sits at one of the top corners of the radiator, usually a small round fitting with a square spindle in the middle. Towel rails have one at the top as well.
Step by step: releasing the air
Turn the heating off and let the radiators cool. Bleeding a hot radiator risks scalding water spitting out, and with the pump running you can pull more air into the system rather than letting it out.
Hold the cloth under the valve, fit the key and turn it slowly anticlockwise by about a quarter of a turn. You should hear a hiss as air escapes. Keep the key in place. When the hissing stops and a steady dribble of water appears, close the valve again by turning clockwise. It only needs to be snug; forcing it can damage the small seat inside.
Work through each radiator that showed the symptom. If you have a two-storey house, start downstairs and finish upstairs, because air tends to rise towards the highest radiators.
Check the boiler pressure afterwards
Every bit of air you release is replaced by water from the system, so the pressure on a sealed system drops slightly. Look at the gauge on the front of the boiler once you have finished. Most sealed systems sit somewhere around 1 to 1.5 bar when cold, but your boiler manual gives the correct figure for your model.
If the needle has fallen below the recommended range, top it up following the manufacturer's instructions. Our guide on how to repressurise a boiler walks through the filling loop. Older open-vented systems fed from a loft tank refill themselves, so there is no gauge to watch.
Turn the heating back on and test
Switch the heating on and give it time to warm through. The radiators you bled should now heat evenly from top to bottom. If some rooms still lag behind others, the system may need balancing rather than bleeding, which is about setting the lockshield valves so water reaches every radiator in fair shares. Our guide to balancing radiators explains that job.
When bleeding keeps coming back
Releasing a little air once or twice a year is normal, particularly after the system has been drained or worked on. Needing to bleed the same radiator every week is not. Repeated air can mean a small leak somewhere drawing air in, a faulty automatic air vent, a pump problem, or corrosion inside the system producing gas.
If the water from the valve is very black or smells unpleasant, that is a sign of corrosion debris. A radiator repair visit or a look at whether a power flush is worthwhile can deal with the root cause instead of the symptom. If the boiler pressure keeps falling as well, read our page on a boiler losing pressure.
Valves that will not turn or will not close
Bleed valves sometimes seize after years of paint and limescale. Do not lean on the key with force, because a snapped spindle leaves you with an open hole and water coming out. Likewise, if the valve will not seal again and keeps weeping, wrap it in a cloth, put a container underneath and call an engineer rather than overtightening it. Replacing a bleed valve or the whole radiator is routine work for us.
Automatic air vents and towel rails
Some systems have an automatic air vent near the boiler or on the highest pipework, a small brass cylinder with a cap that releases air on its own. If that vent sticks open it can weep water, and if it sticks shut it stops doing its job, so air builds up in the radiators instead. Heated towel rails are often the first place air gathers in a bathroom because they are mounted high and have narrow tubes. Bleed them the same way, keeping the cloth close because the bleed point is often awkward to reach behind the rails.
Getting help in Kent and South East London
If you would rather someone else did it, or the radiators stay cold after bleeding, our engineers can find out why. Call 01732 444555 or use our contact page. We open Monday to Friday from 7am to 10pm, and at weekends from 9am to 8pm. Our minimum charge is £90 + VAT, including the first hour on site.